IFT Control Module  IFT-ECM used on Heat n Glo and Heatilator direct vent gas fireplaces with electronic ignition

Electronic parts are non-returnable

here is some explanation of error codes on the ECM

IFT Troubleshooting Diagnostics

 

System Error Codes & Built-in Diagnostics

The IFT has enhanced system diagnostic capabilities in two forms, the ECM LED Error Codes and the RC400 (if equipped).  The authorized service technician shall utilize the information from these sources to direct actions & document the findings.

 

ECM LED Error Codes

ECM LED Error Codes Description 3 Red: 1 Green IFT-RC400 error message:  ‘Appliance Safely Disabled’, pilot sparks for 60 sec, no ignition and/or flame rectification.  Technician shall follow applicable IPI Pilot Ignition and Flame Sensing Rectification troubleshooting guide to resolve the issue. 2 Red: 1 Green IFT-RC400 display:  ‘Error Pilot Flame’, pilot valve solenoid not detected. Technician shall follow applicable gas valve troubleshooting guide to resolve the issue. 2 Red: 2 Green Sparking feedback signal error, spark coil failure.  The module has an internal hardware failure that cannot be repaired.  Replace the control module 5 Red: 1 Green IFT-RC400 display:  ‘Error Power Vent’.  This Error Code only occurs in systems equipped with an approved Powervent Kit.  There are multiple possible causes for this Error Code.  Service Technician shall follow applicable troubleshooting guide for the powervent system to resolve the issue.

 

 

SKU: 2326130